How to evaluate sites when grid and thermal constraints dominate AI capacity - four pillars on one page

By Alex Pawlowski

Published: 2026-09-21

URL: https://thestrategystack.substack.com/p/power-cooling-datacenter-location


Power, Cooling and Datacenter Location cheat sheet with four pillars around an AI datacenter site node and a formula banner for winning site selection.

Upgrade To Paid


After the stack map, site selection decides whether capacity ever turns on.

AI datacenters are power projects that happen to contain computers. Interconnection queues, water use, community politics, and fiber paths can delay or kill projects that looked perfect on a map. Cooling architecture determines whether you can run dense accelerators sustainably - or throttle silently when heat spikes.

Location is not real estate trivia. It is where your compute strategy meets physics and policy.


Four pillars

Power & grid - MW available now vs. promised later; upgrade timelines; price volatility and curtailment risk.

Cooling & thermal - liquid vs. air, water sourcing, PUE targets, ambient climate, heat rejection limits.

Connectivity & latency - fiber diversity, cross-connect costs, distance to users and data sources for inference-heavy workloads.

Land, permitting & buildability - zoning, environmental review, construction labor, expansion footprint for phase two.

Winning site (working formula): deployable power + cooling headroom + connectivity + buildability - weakest pillar caps the rest.


Where site selection fails

-

Power “reserved” but not energised - GPUs ordered into a queue

-

Cooling sized for nameplate, not sustained AI load

-

Latency ignored for inference products - customers feel distance

-

Permitting treated as parallel workstream - on critical path in reality

-

Single-vendor optimism - no plan B region when policy shifts


How to use this framework

1. Score each pillar 1–5 with evidence

No narrative scores; interconnection dates, thermal models, fiber paths.

2. Stress-test the weakest pillar

What breaks at 2× load or 18-month delay?

3. Compare portfolio, not paradise sites

Two good-enough regions beat one perfect slide.

4. Tie site choice to workload

Training-heavy vs. inference-heavy vs. hybrid - pillars weight differently.

Diagnostic questions:

-

Which pillar would block energisation if it slipped six months?

-

Is cooling the hidden cap on rack density today?

-

Would your customers notice if this region disappeared?


Upgrade To Paid

👉 Unlock the Strategy Stack

…and access the Business Model Series, advanced Cheat Sheets, the Operator Vault, and various essays at the intersection of strategy and technology.


In this series →

https://thestrategystack.substack.com/p/physical-economy-ai-collection

Read next →

https://thestrategystack.substack.com/p/the-economics-of-ai-compute

Go deeper →

Explore The Strategy Stack